Verdant
Verdant Energy Management Thermostats for PTAC & VTAC
Verdant Energy Management Thermostats for PTAC & VTAC
Verdant thermostats cut guest-room HVAC runtime by about 45% on average and typically lower energy cost by 15–20%, without changing how the room feels when a guest is in it.
They do it with built-in motion + thermal occupancy sensing, patented Night Occupancy (so the unit does not set back while someone is sleeping), and set-point limits that stop extreme guest settings. Install time is about 10 minutes per room. Wired and wireless models are available. The wireless mesh does not use the property Wi-Fi.
AIDCO supplies Verdant alongside Amana, GE / Hotpoint, Islandaire, Applied Comfort, and Distinctions PTAC / VTAC units. One quote. One Canadian supplier. GTA installation and aftercare available.
What you get in the number
- ~45% less HVAC runtime in vacant rooms (Verdant published average)
- ~15–20% lower energy cost on the rooms those units serve
- 12–18 month typical payback, faster when utility incentives apply
- ~10 minute install per thermostat — retrofit or new build
- Approved by major hotel brands including Hilton, Marriott, and IHG programs
- Ontario Save on Energy Retrofit currently lists Hotel Occupancy Control incentives of $100/room (gas heat) and $200/room (electric heat) for HVAC + lighting occupancy control. AIDCO will help you check current eligibility before you order.
How it works
- The thermostat watches the room with a motion sensor and a thermal sensor.
- When the room is empty, temperature setback starts automatically. Limits keep the room from drifting too far.
- When a guest returns, Dynamic Intelligent Recovery brings the room back to the set point within the time you allow.
- Night Occupancy keeps setback off while a sleeping guest is detected — no door switch required.
- Optional online management (Verdant Thermostat Manager) lets you see and adjust every room from a phone or desktop. The mesh network is proprietary 900 MHz RF. It does not sit on guest Wi-Fi.
Models we quote
Most hotel and LTC PTAC jobs land on the VX / VX4 family. ZX is the flagship guest-facing design (e-paper display). We match the model to the unit, voltage, and whether you want standalone or networked rooms.
| Family | Best fit | Occupancy | Install | Display |
|---|---|---|---|---|
| VX / VX4 | PTAC, PTHP, VTAC, fan coil, most hotel retrofits | PIR + thermal (occupancy models) | Wired or wireless | LCD, black or white |
| VX4-GEA | GE / Hotpoint Zoneline V12 and make-up air PTACs | Yes | Plug-and-play harness | LCD |
| ZX | New builds and brand-standard guest rooms | Yes + Night Occupancy | Wired or wireless | E-paper |
Common part families: VX4-TR (wired), VX4-TW (wireless), VX4-HW (line voltage wireless), VX-TR-KT / VX-TW-KT, ZX wired/wireless. Black or white. Networked (-XMF) or standalone.
PTAC and VTAC compatibility
Verdant is built for the equipment AIDCO already ships:
- PTAC and PTHP with electric heat
- VTAC / VTHP
- Fan coil (2-pipe and 4-pipe, PSC and ECM)
- Water-source heat pump
- Selected VRF / mini-split (LG, Mitsubishi, Carrier, Daikin, Toshiba, Fujitsu, Hitachi — model-specific)
- GE / Hotpoint Zoneline including newer V12 and make-up air chassis (VX4-GEA)
If you already run Amana, GE Zoneline, Hotpoint, Islandaire, Applied Comfort, or Distinctions units, send the model number. We confirm terminals (R, C, Y, W, O/B, GH, GL, AUX) before we quote.
Who this is for
- Hotels and motels replacing wall stats on PTAC / VTAC rooms
- LTC and senior living that need set-point limits and quieter overnight operation
- Student housing and multifamily with random occupancy
- Owners doing a PTAC refresh who want the thermostat and the unit from one Canadian supplier
What AIDCO handles
- Model selection against your existing PTAC / VTAC chassis
- Bulk pricing for full-floor and full-property rollouts
- Canada-wide supply
- Installation in the GTA / Southern Ontario
- Help checking Ontario Save on Energy Retrofit occupancy-control incentives
Warranty (manufacturer)
- Hardware: 1 year against defects in materials and workmanship under normal use
- Software: 1 year that it performs in substantial conformance to published specifications
- Replacement units carry 90 days or the remainder of the original term, whichever is longer
Request a quote
Pricing is quoted. Volume, model mix (wired vs wireless, networked vs standalone), and rebate path all change the number.
Send:
- Property type and room count
- PTAC / VTAC brand and model (or a photo of the existing thermostat + unit data plate)
- Wired or wireless preference
- City
Call 1-888-302-4326 or email info@aidco.ca.
Share

How Can We Help?
We supply across Canada and North America. Installations & Service is available for GTA Residents!
Check out our F.A.Q or Check Out The Ultimate PTAC Guide!
Toll Free: 1-888-302-4326
Feel Free to use the Contact form below for direct email messaging or use anyone of the bottom right green buttons for Email, SMS, WhatsApp, or a quick Phone Call!